Publications

Congo Red Staining in Digital Pathology: The Streamlined Pipeline for Amyloid Detection Through Congo Red Fluorescence Digital Analysis  (2023)

Authors:
Cazzaniga, Giorgio; Bolognesi, Maddalena Maria; Stefania, Matteo Davide; Mascadri, Francesco; Eccher, Albino; Alberici, Federico; Mescia, Federica; Smith, Andrew; Fraggetta, Filippo; Rossi, Mattia; Gambaro, Giovanni; Pagni, Fabio; L'Imperio, Vincenzo
Title:
Congo Red Staining in Digital Pathology: The Streamlined Pipeline for Amyloid Detection Through Congo Red Fluorescence Digital Analysis
Year:
2023
Type of item:
Articolo in Rivista
Tipologia ANVUR:
Articolo su rivista
Language:
Inglese
Format:
Elettronico
Referee:
No
Name of journal:
Laboratory Investigation
ISSN of journal:
0023-6837
N° Volume:
103
Number or Folder:
11
Page numbers:
1-9
Keyword:
Congo Red fluorescence; amyloidosis; digital pathology; renal biopsy
Short description of contents:
: Renal amyloidosis is a rare condition caused by the progressive accumulation of misfolded proteins within glomeruli, vessels and interstitium, causing functional decline and requiring prompt treatment due to its significant morbidity and mortality. Congo Red (CR) stain on renal biopsy is the gold standard for the diagnosis, but the need for polarized light is limiting the digitization of this nephropathology field. This study explores the feasibility and reliability of CR fluorescence on virtual slide (CRFvs) evaluating the diagnostic accuracy and proposing an automated digital pipeline for its assessment. Whole slide images (WSI) from 154 renal biopsies with CR were scanned through Texas red fluorescence filter (Nanozoomer S60, Hamamatsu) at the digital Nephropathology Center of IRCCS San Gerardo, Monza, Italy, were evaluated double blinded for the detection and quantification through Amyloid Score (AS) and a custom ImageJ pipeline was built to automatically detect amyloid containing regions. Inter-observer agreement for CRFvs was optimal (k=0.90, 95%CI=0.81-0.98), with even better concordance when consensus-based CRFvs evaluation was compared to the standard CR birefringence (BR, k=0.98, 95%CI=0.93-1). Excellent performance was achieved in the assessment of AS overall by CRFvs (Wk=0.70, 95%CI=0.08-1), especially within the interstitium (Wk=0.60, 95%CI=0.35-0.84), overcoming the misinterpretation of interstitial and capsular collagen birefringence. The application of an automated digital pathology pipeline (Streamlined Pipeline for Amyloid detection through congo red fluorescence Digital Analysis, SPADA) further increased the performance of pathologists, leading to a complete concordance with the standard BR. This study represents an initial step in the validation of CRFvs, demonstrating its general reliability in a digital nephropathology center. The computational method used in this study has the potential to facilitate the integration of spatial omics and artificial intelligence tools for the diagnosis of amyloidosis, streamlining its detection process.
Note:
Online ahead of print Aug 25
Product ID:
135081
Handle IRIS:
11562/1103286
Last Modified:
January 30, 2025
Bibliographic citation:
Cazzaniga, Giorgio; Bolognesi, Maddalena Maria; Stefania, Matteo Davide; Mascadri, Francesco; Eccher, Albino; Alberici, Federico; Mescia, Federica; Smith, Andrew; Fraggetta, Filippo; Rossi, Mattia; Gambaro, Giovanni; Pagni, Fabio; L'Imperio, Vincenzo, Congo Red Staining in Digital Pathology: The Streamlined Pipeline for Amyloid Detection Through Congo Red Fluorescence Digital Analysis «Laboratory Investigation» , vol. 103 , n. 112023pp. 1-9

Consulta la scheda completa presente nel repository istituzionale della Ricerca di Ateneo IRIS

<<back

Activities

Research facilities

Share