Pubblicazioni

Physiologic Evaluation of Coronary Lesions Using Instantaneous Wave-free Ratio (iFR) in Patients with Severe Aortic Stenosis Undergoing Trans-catheter Aortic Valve Implantation  (2018)

Autori:
Scarsini, Roberto; Pesarini, Gabriele; Zivelonghi, Carlo; Piccoli, Anna; Ferrero, Valeria; Lunardi, Mattia; Gottin, Leonardo; Zanetti, Claudia; Faggian, Giuseppe; Ribichini, Flavio Luciano
Titolo:
Physiologic Evaluation of Coronary Lesions Using Instantaneous Wave-free Ratio (iFR) in Patients with Severe Aortic Stenosis Undergoing Trans-catheter Aortic Valve Implantation
Anno:
2018
Tipologia prodotto:
Articolo in Rivista
Tipologia ANVUR:
Articolo su rivista
Lingua:
Inglese
Referee:
No
Nome rivista:
EUROINTERVENTION
ISSN Rivista:
1969-6213
N° Volume:
13
Numero o Fascicolo:
13
Intervallo pagine:
1512-1519
Parole chiave:
aortic stenosis, fractional flow reserve, other technique, transcatheter aortic valve implantation (TAVI)
Breve descrizione dei contenuti:
Aims: We sought to assess eventual changes in iFR measurements in patients with aortic stenosis (AS) before and after TAVI in coronary lesions with different degrees of angiographic severity. Methods and results: The functional relevance of 145 coronary lesions was assessed by online iFR and FFR measurement in 66 patients with severe AS before and after TAVI, during the same procedure. The iFR-FFR classification agreement was calculated for pre-TAVI and post-TAVI measurements. Mean iFR values remained identical before and after TAVI, irrespective of the angiographic severity of the coronary stenosis (0.89 +/- 0.12 vs. 0.89 +/- 0.12, p=0.66). However, individual iFR values varied widely after TAVI and the 0.89 iFR threshold was crossed by 15% of the investigated coronary lesions. Higher iFR variation was related to a higher transaortic gradient drop after valve intervention. The diagnostic accuracy of iFR in predicting an FFR <= 0.8 was poor (65%) in lesions with severe obstructions, and tended to increase post TAVI. Conclusions: Although overall values did not change after TAVI, iFR presented significant and mostly erratic individual variations after valve replacement. Delta iFR was influenced by the extent of the transaortic gradient drop induced by TAVI. Therefore, caution is advisable in the interpretation of iFR in the presence of AS.
Id prodotto:
101381
Handle IRIS:
11562/974866
ultima modifica:
9 novembre 2022
Citazione bibliografica:
Scarsini, Roberto; Pesarini, Gabriele; Zivelonghi, Carlo; Piccoli, Anna; Ferrero, Valeria; Lunardi, Mattia; Gottin, Leonardo; Zanetti, Claudia; Faggian, Giuseppe; Ribichini, Flavio Luciano, Physiologic Evaluation of Coronary Lesions Using Instantaneous Wave-free Ratio (iFR) in Patients with Severe Aortic Stenosis Undergoing Trans-catheter Aortic Valve Implantation «EUROINTERVENTION» , vol. 13 , n. 132018pp. 1512-1519